NMS is Integrated to Improve Network Management Efficiency
PLANET GS-2210-16P2S Smart Ethernet switch combined with NMS makes network management easier and more efficient. In addition, it is easy to configure whatever application that the industry needs. It features link aggregation, IGMP, QoS, PoE schedule and more to improve the availability of critical business applications.
The GS-2210-16P2S provides 16 10/100/1000BASE-T ports featuring 32-watt 802.3at PoE+ and 2 additional Gigabit SFP slots. With a total power budget of up to 240 watts for different kinds of PoE applications, it provides a quick, safe and cost-effective Power over Ethernet network solution for small businesses and enterprises.
Through the NMS, administrators can centrally manage networks of up to 102,400 nodes from a central office, thereby greatly improving network and power management efficiency. With its user authentication management, combined with the NMS, the security of data transmission in modern factory automation systems is enhanced.
UNI-NMS Remote Management Solution
The GS-2210-16P2S supports PLANET's Universal Network Management System (UNI-NMS) helping IT staff by remotely managing all network devices and monitoring PDs' operational statuses. Thus, they're designed for both the enterprises and industries where deployments of PDs can be as remote as possible, without having to go to the actual location once a bug or faulty condition is found. With the UNI-NMS, all kinds of businesses can now be speedily and efficiently managed from one platform.
Powerful NMSViewerPro Solution that Meets Evolving Network Management Challenges
The GS-2210 Web Smart Switch series, known for such features as QoS, Link aggregation, PoE, VLANs, IGMP, and so on, provides an eye-catching feature called NMS developed by PLANET to easily and remotely manage and monitor network devices in the local environment from mobile app. This feature not only improves operational convenience, but also ensures users to have real-time control over their network infrastructure. It provides users with an unparalleled experience.
The intuitive interface of the local NMSViewerPro allows administrators to easily perform a variety of tasks, including monitoring traffic, setting configuration, troubleshooting, and more. At the same time, PLANET UNI-NMS application provides real-time alerts and notifications, allowing administrators to respond to any emergency situations anytime, anywhere to ensure the stable operation of the network.
The introduction of this feature demonstrates our sensitivity to user needs and our commitment to providing a comprehensive and powerful solution to meet evolving network management challenges. We firmly believe that this feature of supporting local NMSViewerPro will bring users a more efficient and flexible management experience.
PLANET NMS and NMSViewerPro app, which with PLANET's free cloud service, allow users to quickly and easily detect, configure, deploy and manage devices remotely. You can just scan the NMS agent's (NMS-500/NMS-1000V) QR code using the mobile application to easily monitor and control the remote network devices via the private cloud.
Built-in Unique PoE Functions for Powered Devices Management
As it is the managed PoE switch for surveillance, wireless and VoIP networks, the GS-2210-16P2S features the following special PoE management functions:
Intelligent Powered Device Alive Check
The GS-2210-16P2S can monitor connected PD status in real time via PD alive check function. Once the PD stops working and responding, the GS-2210-16P2S will resume the PoE power and bring the PD back to work. It will greatly enhance the network reliability through the PoE port resetting the PD’s power source and reducing administrator management burden.
PoE Schedule for Energy Savings
Under the trend of energy savings worldwide and contributing to environmental protection, the GS-2210-16P2S can effectively control the power supply besides its capability of giving high watts power. The “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money. It also increases security by powering off PDs that should not be in use during non-business hours.
PoE Usage Monitor and Power Control
Through the power usage chart in the web management interface, the GS-2210-16P2S empowers administrators to real-time monitor the power usage status of connected PDs. This capability significantly improves facility management efficiency. Additionally, the switch allows for timely activation or deactivation of PoE ports, providing the ability to power off or reboot connected PDs as needed.
Robust Layer 2 Features
The GS-2210-16P2S can be programmed for basic switch management functions such as port speed configuration, port aggregation, VLAN, bandwidth control and IGMP snooping. This switch provides 802.1Q tagged VLAN Protocol functions. By supporting port aggregation, the GS-2210-16P2S allows the operation of a high-speed trunk combined with multiple ports, and supports fail-over as well. Also, the Layer 2 protocol included to help discover basic information about neighboring devices on the local broadcast domain.
Flexibility and Long-distance Extension Solution
The two mini-GBIC slots built in the GS-2210-16P2S support SFP auto-detection and dual speed as it features 100BASE-FX and 1000BASE-SX/LX SFP (Small Form-factor Pluggable) fiber transceivers to uplink to backbone switch and monitoring center in long distance. The distance can be extended from 550 meters to 2 kilometers (multi-mode fiber) and up to above 10/20/30/40/50/70/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions.
Convenient and Smart ONVIF Devices with Detection Feature
PLANET has newly developed an awesome feature -- ONVIF Support -- which is specifically designed for cooperating with video IP surveillances. From the GS-2210-16P2S GUI, you just need one click to search and show all of the ONVIF devices via network application. In addition, you can open the camera web page via the IP address link to get real-time monitoring information and online/offline status through IP-based camera, and perform PoE restart control from the GS-2210-16P2S GUI.
ONVIF management functions:
PLANET NMSViewerPro Networking Solution
The GS-2210-16P2S effortlessly integrates the functionalities of PLANET NMS and NMSViewerPro, providing users with a seamless and intuitive experience. Leveraging the internet connectivity feature of smartphones enables real-time monitoring of network traffic, configuration settings, and troubleshooting execution. It can access a wealth of device information stored in the cloud, allowing for a comprehensive understanding of your network. Users can benefit from real-time monitoring and control of access points, regardless of their location or time zone.
Department/Workgroup 802.3at PoE+ Network
Providing 16 PoE+ in-line power interfaces, the GS-2210-16P2S can easily build a power that centrally controls IP phone system, IP camera system and wireless AP group for enterprises. The GS-2210-16P2S delivers full ports of 802.3af/at compliant Gigabit Ethernet network connectivity with high-performance and cost-effective advantages for the increasing number of PoE IP telephones, PoE IP cameras, PoE wireless access points and other devices applied at the edge of the small or medium enterprise network.
Physical Ports
Layer 2 Features
Quality of Service
Multicast
Security
Management
Power over Ethernet
Hardware Specifications | |
---|---|
Copper Ports | 16 10/100/1000BASE-T RJ45 copper ports |
PoE Injector Port | 16 ports with 802.3af/802.3at PoE+ injector function |
SFP Slots | 2 x 100/1000BASE-X SFP interface |
Flash Memory | 16Mbytes |
Reset Button | < 10 sec: System reboot > 10 sec: Factory default |
ESD Protection | Contact ±6KV , Air ±8KV |
Surge Protection | Differential mode ±2KV , Common mode ±4KV |
Dimensions (W x D x H) | 440 x 207 x 44mm |
Weight | 2343g |
Power Consumption | 7.1 watts / 24.2BTU (System) 283 watts/ 965BTU (System+PoE) |
Power Requirements | AC 100~240V, 50/60Hz |
Fan | 2 |
LED | System: PWR (Green) PoE Usage 80% (Green) Ports: LNK/ACT (Green) PoE-in-Use (Amber) |
Switching Specifications | |
Switch Architecture | Store-and-forward |
Switch Fabric | 36Gbps/non-blocking |
Switch Throughput | 26.78Mpps |
Address Table | 8K MAC address table with auto-learning, auto-aging |
Shared Data Buffer | 4.1MB |
Jumbo Frame | 10KBytes |
Flow Control | Back pressure for half duplex IEEE 802.3x pause frame for full duplex |
Power over Ethernet Specifications | |
PoE Standard | IEEE 802.3at PoE+ PSE |
PoE Power Supply Type | End-span |
PoE Power Output | 32W (max.) |
Power Pin Assignment | 1/2(+), 3/6(-) |
PoE Power Budget | 240 watts (max.) |
Layer 2 Functions | |
Port Configuration | EEE Green energy savings disable/enable Port disable/enable/reboot Flow control disable/enable Bandwidth control on each port Port loopback protection |
Port Status | Display each port’s speed duplex mode, Display link status Display flow control status Display auto negotiation status Display Green energy saving status |
Port Mirroring | In / Out / All Many-to-1 monitor |
VLAN | 802.1Q tagged VLAN, up to 16 VLAN groups |
Bandwidth Control | TX/RX/Both |
Link Aggregation | static trunk Supports 8 groups with 8 ports per trunk group |
QoS | 8 priority queues on all switch ports Supports strict priority and Weighted Round Robin (WRR) CoS policies Traffic classification: IEEE 802.1p CoS/ToS IPv4 DSCP Port-based WRR |
Multicast | IPv4 IGMP v1/v2 snooping Up to 256 |
Security Functions | |
Security | Port isolation DHCP Snooping |
Switch Management Functions | |
System Configuration | Telnet, Web browser |
Management | Authentication for IPv4 Telnet user name and password Telnet Cable Diagnostics IP address or domain name Ping Test NTP (Network Time Protocol) PLANET Smart Discovery Utility PLANET NMS PLANET NMSViewerPro |
Standard Conformance | |
Regulatory Compliance | FCC Part 15 Class A, CE |
Standards Compliance | IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3z Gigabit 1000BASE-SX/LX IEEE 802.3ab Gigabit 1000BASE-T IEEE 802.3x flow control and back pressure IEEE 802.1p Class of Service IEEE 802.1Q VLAN tagging IEEE 802.3af Power over Ethernet IEEE 802.3at Power over Ethernet PLUS RFC 783 TFTP RFC 791 IP RFC 792 ICMP RFC 2068 HTTP RFC 1112 IGMP v1 RFC 2236 IGMP v2 |
Environment | |
Operating | Temperature: 0 ~ 50 degrees C Relative Humidity: 5 ~ 90% (non-condensing) |
Storage | Temperature: -10 ~ 70 degrees C Relative Humidity: 5 ~ 90% (non-condensing) |
Date | Version | Description | Download |
---|---|---|---|
2024-04-26 | 1.0 | GS-2210-16P2S |
Date | Version | Description | Download |
---|---|---|---|
2024-02-06 | 1.1 | Initial release. |
Date | Version | Description | Download |
---|---|---|---|
2024-07-31 | 1.0 | Initial release. |
Date | Version | Description | Download |
---|---|---|---|
2024-09-13 | 1.0 | EC Declaration. |
Ordering Information | |
---|---|
GS-2210-16P2S |
16-Port 10/100/1000T 802.3at PoE + 2-Port 1000X SFP Web Smart Ethernet Switch |